Quanto Gas Meter CPT-01

CPT-01 & CPT-01S
Quantometer
for secondary measurements
CPT-01 Quantometers have been designed in order to provide our customers with reliable and inexpensive measuring instruments for secondary flow measurements. Our great experience in designing and manufacturing of turbi- ne and rotary gas meters resulted in the development of indu- strial quantometers.
Taking into account our customers’ demands we created the instrument with excellent metrological characteristics and opera- ting performance close to performances of the turbine gas meters designed for custody transfer measurements. Other advantages of the CPT-01 Quantometers are as follows: high quality, easy maintenance, wide range of external devices that can co-operate with the quantometers, e.g. volume correctors, data loggers, data transmission systems. Due to that the CPT-01 Quantometers are well accepted by our domestic and foreign customers.
2
5
The basic components of the CPT-01 Quantometer are as follows:
pressure resistant meter housing (1)
inlet flow straightener (2)
measuring cartridge with the turbine wheel (3)
magnetic coupling as the transferring element between measuring cartridge and the index head (4)
index head (5)
maximum operating pressure: 20 bar suitable for PN16, PN20 ANSI 150 connection flanges
nominal diameter: DN25 up to DN200
meter housing: aluminium or steel (DN200)
flow:
2,5 to 2500 m3/h
rangeability:
up to 1:30
(depending on the meter)
temperature range:
gas temperature: -25°C to +70°C
ambient temperature: -25°C to +70°C
operating position: horizontal or vertical
measurement accuracy: Q,+Qmx < ±1,5% Qmin + Q, < ±3,0%
allowed medias: see Table 5

COMMON
Pressure loss
CPT-01 Quantometer for Secondary Measurements
Pressure drop during the gas flow through the quantometers is determined for air at atmospheric conditions. Maximum value of the Apmax pressure drop for every CPT-01 Quantometer is given in table 1. This value was established during tests carried out at Q with air (p = 1,2kg/m3 density). At real condi- tions Appressure drop may be calculated with the following formula:
Definitions:

maximum flow of the quantometer (according to Table 1) [m3/h] flow at real conditions [m/h]
Table 5: Physical properties of the most popular gases that may be measured by CPT-01 Quantometer. Density at 101,325kPa and 20°C.
Outputs
As an option the meters can be provided with maximum 8 pulse transmitters
2 off LFK-low frequency reed contact pulse sensor
2 off LFI – low frequency inductive pulse sensor (NAMUR)
2 off HF-inductive pulse sensors in the index head (NAMUR) – HF1, HF2
1 off HF-inductive pulse sensors in the meter body (NAMUR)-HF3
AFK – anti-fraud reed contact (available as an option)
Electrical outputs – Amphenol TUCHEL
Index housing made of aluminium what perfectly protects index head against accidental damages
Index housing may be provided with two separate sockets
1 pressure measurement tap
3-way valve-recommended for making connecions with pressure sensor of EVC


Gas
Chemical symbol (formula)
Density p
[kg/m3]
Density related to air
Execution

Standard IIB
Description of pulse sensor connections
Connection Socket 1
lead no
pulse sensor
Socket 2 pulse sensor
Connection HF over lead no
turbine wheel

Index head with encoder (option)
Index head with mechanical output (option)
JACOMMON
ISO9001&14001 certified