DESCRIPTION:

The S23 regulators are a new line of pressure regulators – direct operating type – designed to guarantee a high regulation accuracy and a utmost easiness in use. These devices are usually used in distribution and industrial systems and are de- signed to be installed in regulation units in gas grids of natural, manufactured and Ipg gas or other non corrosive gases, filtered at first. The S23 pressure regulators are “fail to open” type, which means that in case of malfunction due to break- ing of the main diaphragm or as a result of a lack of impulse downstream, the regulator will open up completely. The S23 pressure regulators are “top entry” type, which allows for maintenance operations without having to remove the body from the pipes. Modularity allows for variation in its configuration even when already installed in stream. In addition, the modules can be easily disassembled for eventual controls.

Available version:

.BP
for an inlet pressure range of 0,5 ÷ 5 bar
for an outlet pressure range of 10 ÷ 150 mbar
.MP
for an inlet pressure range of 0,5 ÷ 5 bar
for an outlet pressure range of 10 ÷ 500 mbar
.AP
for an inlet pressure range of 0,5 ÷ 5 bar
for an outlet pressure range of 500 ÷ 4000 mbar
APA
for an inlet pressure range of 0,5 ÷ 5 bar
for an outlet pressure range of 500 ÷ 4000 mbar
.APS (NOT COUNTERBALANCED)
for an inlet pressure range of 2 ÷ 20 bar
for an outlet pressure range of 500 ÷ 4000 mbar

Materials:

  • Body in cast iron (GJS-400-18LT) or steel (ASTM A352 LF2)
  • Covers in pressed steel
  • Diaphragms in rubber with cloth enforcement
  • Seats in stainless steel
  • Springs in stainless steel
  • Available with internal pressure pulse only

Features:

  • Counterbalanced regulating device
  • Anti-pumping device
  • Diaphragm shock adsorber or relief valve
  • Top entry construction
  • In accordance to 2014/68/UE – EN334
  • Working Temperature: -20 (-30) ÷ 60
  • Regulating Class: up to 5
  • Closing Pressure Class: up to 10

Technical data:
AVAILABLE VERSIONS:
· B: WITH OPSO/UPSO SHUT-OFF VALVE
. M: WORKING AS MONITOR

INLET PRESSURE OUTLET PRESSURE  

CG (VALVE COEFFICIENT)

 

CONNECTIONS

BP, MP, AP APS APA BP MP AP, APS AP, APA
BAR MBAR
S23- 1 5 or 6  

 

19

 

 

14 ÷ 80

 

 

75 ÷ 500

 

 

470 ÷ 2000

 

 

2000 ÷ 4000

DN50
S23- 2 5 or 6 3380 DN80

Dimension:

The choice of the regulator is made using the Cg valve coefficient.

Cg coefficient is numerically equivalent to the value of air flow in Scfh in critical conditions with full open regulator operating with an upstream pressure of 1 psia and a temperature of 15° C.

Flow rates with maximum operating at different operating conditions can be calculated as follows:

a. in non critical conditions (when Pe < 2 Pa)

 

b. in critical conditions (when Pe ≥ 2 Pa)

Q=capacity [Stm3/h]

Pe= absolute upstream pressure [bar] Pa= absolute downstream pressure [bar]

OPERATING PRINCIPLE

The operating principle for the S23 regulators is the same as for all models, with the exception of certain marginal differences, exemplified below.

The operating principle for the S23 regulators is the same as for all models, with the exception of certain marginal differences, exemplified below. The S23 pressure regulator is a direct action type instrument with pressure control downstream through external impulse (A).

The downstream pressure is controlled by comparing the spring load (B) and the thrust deriving from the downstream pressure on the diaphragm (C). The diaphragm’s movement is transmitted by the lever system (D) to the rod (E). The rubber pad (F) is vulcanized on the stopper and assures hermetic closing when the required capacity is nil. If during operation the thrust deriving from the downstream pressure is less than the spring load (B), the diaphragm (C) lower itself, and draws the stopper (F) away from the valve housing until the downstream pressure once again attains the pre-set calibration value.

The regulator has incorporated two anti-pumping devices (H) that have the function of slowing the inflow / outflow of the gas to the head in the transitory phases in order to eliminate possible phenomena of commutation.

Overall Dimension:

  H A B C D F E
DN 65 DN 80 DN 100 OUTLET PRESSURE RANGE (MBAR)
  MM MM MM
S23-1 B   298   750 960 500 210 160 630 630 TR 380 380 TR
10 ÷ 80 75 ÷ 500 470 ÷ 2000 1900 ÷ 4000

 

 Installation s23: